4 Waterford E61 Gas Fireplace Insert
This is a copy of the label that accompanies
each Waterford E61-NG Gas Insert Natural
Gas. We have printed a copy of the contents
here for your review. The safety label is located
on the right side door panel.
NOTE: Waterford units are constantly being
improved. Check the label on the unit and if there
is a difference, the label on the unit is the correct
one.
SAFETY LABEL
For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfitter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, flexible
connectors shall not exceed 36 inches in
length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
DUPLICATE SERIAL NO.
DO NOT REMOVE OR COVER THIS LABEL /
NE PAS ENLEVER CETTE TIQUETTEÉ
205
205
FPI Fireplace Products International Ltd., Delta, BC, Canada
Serial no./
No de serie
908-419b
Made in Canada/Fabrique au Canada
ÉÉQUIP A L'UISINE POUR GAZ NATURAL
5" WC/C.E. (1.25 kPa)
3.8" WC/C.E. (0.94 kPa)
1.1" WC/C.E. (0.27 kPa)
#33 DMS (2.87mm)
200
36,100 Btu/h (10.57 Kw/h)
18,000 Btu/h (5.28 Kw/h)
0-4500 ft/pi (610-1372m)
Minimum supply pressure
Manifold pressure High
Manifold pressure Low
Factory Equipped for Altitude 0-2000 ft.
Maximum Input
Minimum Input
Orifice size
Altitude
Convertible to 27,000 Btu for Altitude 0 - 4500 ft. with Kit #: 260-920
Maximum Input
Minimum Input
Orifice size
Altitude
Convertible for Altitude 2000-4500 ft.
Maximum Input
Minimum Input
Orifice size
Altitude
FACTORY EQUIPPED FOR NATURAL GAS Model:E61NG
Pression d'allimentation minimum
Pression la tubulure d' chappement lev e
Pression la tubulure d' chappement basse
à
à
ééé
é
38,000 Btu/h (11.14 Kw/h)
19,000 Btu/h (5.57 Kw/h)
#32 DMS (2.9mm)
0-2000 ft/pi (0-610m)
27,000 Btu/h (7.91 Kw/h)
13,500 Btu/h (3.95 Kw/h)
#40 DMS (2.49mm)
0-4500 ft/pi (0-1372m)
D bit Calorifique maximum
D bit Calorifique minimum
Dimensions de l'orifice
L'altitude
é
é
D bit Calorifique maximum
D bit Calorifique minimum
Dimensions de l'orifice
L'altitude
é
é
D bit Calorifique maximum
D bit Calorifique minimum
Dimensions de l'orifice
L'altitude
é
é
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an
aftermarket, permanenlty located,manufactured (mobile) home where not prohibited by local codes. See owner's
manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used.
A
B
Minimum Clearances
to Combustibles/
Degagement Minimum
De Materiaux Combustibles
Unit to Sidewalls A 9"/230mm
Top of Hob to mantel:
unshielded B 16"/406mm
shielded B 12"/305mm
To ceiling from top of stove: 36"/ 915mm
A floor protector consisting of one layer of ½" thick
WonderBoard , Durock , or equivalent extending
at least 9" in front of the face of the unit and the full
width of the front surface is required.
Floor Protector
This appliance must be installed in accordance with
local codes, if any; if none, follow the National Fuel
Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and
Propane Installation Codes, CSA B149.1.
FOR USE WITH GLASS DOORS CERTIFIED
WITH APPLIANCE ONLY.
This vented gas fireplace heater is
not for use with air filters.
Not for use with solid fuel.
Electrical Supply (115 V, 1.13A, 60 Hz)
Approved for use with Emerald Zero Clearance Kit, Part No. 270-900.
Listed:
Report No.
VENT GAS FIREPLACE HEATER
476-1714-00 (Oct. 1999)
Certified for/Certifi e pour: CANADA and U.S.A.é
ANSI Z21.88b-2003/CSA 2.33b-2003, /CGA 2.17-M91Tested to: CAN