13Waterford E61 Gas Fireplace Insert
5) Place the two Small Side Logs beside the
burner on the firebox floor, as shown in
diagram 4.
6) Distribute the embers along the front burner
but do not cover the burner ports and
around the logs. Place the embers on the
floor of the firebox. Place the lava on the
burner tray in front of the left and right front
logs. See Diagram 4.
Diagram 4
Diagram 3
Diagram 1: Do not force logs down.
Diagram 2
3) Place the left front log, carefully sliding it
down onto the left pins of the front burner.
See diagram 2.
LOG INSTALLATION
WARNING: Dangerous operating
conditions may occur if these logs
are not positioned in their approved
locations. Read the instructions
below carefully and refer to the
diagrams. If logs are broken do not
use the unit until they are replaced.
Broken logs can interfere with the
pilot and burner operation.
OPTIONAL DOOR
GRILL
1) Remove the door by lifting it slightly up and
off the front face.
Secure the Door Grill to the
Door with 2 screws.
INSTALLATION
2) Remove the 2 side screws.
3) Position the door grill inside the door and
secure with the 2 screws.
4) Place the right front log, carefully sliding it
down onto the right pins of the front burner.
See diagram 3.
a) Front Right Log - Part # 902-020
b) Front Left Log - Part # 902-021
c) Rear log - Part # 902-022
d) Embers - Part # 902-151 (1 bag)
e) Lava - Part # 902-154 (1 bag)
(Part # 560-935 for the set of three logs)
1) Remove the logs from the box and carefully
unwrap them. The logs are fragile, handle
with care - DO NOT FORCE into position.
2) Place the rear log, carefully sliding it down
onto the pins, with the flat side of the log
facing the back of the unit. See diagram 1.
OPTIONAL WALL
THERMOSTAT
A wall thermostat may be installed if desired.
Connect the wires as per the wiring diagrams.
Note that the wires are connected to the "TH"
on the gas valve. Use table below to determine
the maximum wire length:
Note: Preferable if the thermostat is in-
stalled on an interior wall.
Waterford offers an optional programmable
thermostat but any 250-750 millivolt rated non-
anticipator type thermostat that is CSA, ULC or
UL approved may be used.
CAUTION
Do not connect the millivolt
wall thermostat wires
to the 120V wires.
Thermostat Wire Table
14 GA.
16 GA.
18 GA.
20 GA.
22 GA.
50 Ft.
32 Ft.
20 Ft.
12 Ft.
9 Ft.
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size Max. Length